The Leybold Coolpak CP 4000 Coldhead Compressor interface cable is not correct.What is the Part Number for the Leybold R…

The Leybold Coolpak CP 4000 Coldhead Compressor interface cable is not correct.What is the Part Number for the Leybold RW4000 Compressor Interface Cable That Connects to the Magnet Monitor devices.Mag…

Symptom

What is the Part Number for the Leybold RW4000 Compressor Interface Cable That Connects to the Magnet Monitor devices The cable kit that comes with a system upgrade has the adapter cable for the Sumitomo compressor but not for the Leybold RW4000 compressor.

Applies to

Product
Magnet Monitor 3. Magnet Monitor 3 Magnet Monitor 3
Software
Magnet Monitor 3 Revision 1.56. Magnet Monitor 3 revision 1.56, distributed to sites with Connectivity automatically post FMI 60755 release on 6/23/2008. See Long Description for Fixes and Notes. Magnet Monitor 3 Revision 1.56 Software (formerly known as 1.55). Fixes New magnet type selection page with menus for both compressors. New remote commands to change the compressor selections. New uploaded properties to show the current compressor selections. A fix to the satellite interface so MM3 doesn't lose the sat link if it gets a malformed entitlement message. Changed configuration files so ABM and BOM magnets with DT500 sensors use the correct lookup tables. Disabled alarms actually won't generate alarms. The net mask no longer has to be entered with extra zeros (i.e. - 255.0.0.0 is now good enough instead of 255.000.000.000). The "Show Digital IO" web page shows all compressor types correctly - no more messages saying that Leybolds are inverted. New alarm limits for ABM and BOM for 2nd_stage_shield (is now 10K to 25K, was previously 3.5K to 10K). Changed Master Interval to 720 minutes for LCC and Non-Zero boil off magnets and 360 minutes for HFOs to reduce dispatch volume. NOTES •Software will be downloaded to all communicating sites except satellite modems. •Currently there is no CD that is orderable as a FRU for sites that do not have communication or have a satellite modem so that the software can be manually updated.
Component
2116875 Cable, Leybold RW4000 Compressor Adaptor, 8" Part Number 2116875, Leybold RW4000 Compressor Interface Cable Assembly, (Run 833B) FJ4 TO MS5-A1-A6-JR, (used on Leybold RW4000 compressors). Previously documented obsoleted cable part number 46-328000G988. Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. FEMC GPRS data as of 3/37/2008. For most up-to-date information check with MR Service Documentation or in FEMC Parts Availibility . Part #: 2116875 Part Type : GP CONSUMABLES Part Weight: 0.45 LBR Repairable : No Returnable : No Hazardous Material : N Description: CABLE, LYBOLD COMPRESSOR ADAPTOR, 8" FRU : Yes Status : Orderable Parts Offered as : Current : 2116875 Harvested : Not Available Exchange : Not Available Comments : FLS - LEYBOLD COMPRESSOR ADAPTER, 8"9-PIN SUB-D TO BURNDY CONNECTOR. DISTRIBUTION TO THEFIELD HAS BEEN COMPLETED. ORDERS SHOULD NOW BE PROCESSEDTHRU CARES PER J. DIER. USAGE SHOULD BE MINIMAL. 1-95, A. WAGNER LEYBOLD CABLE ADAPTER USED WITH EDM4. MINIMUM BUY IS 50, LEADTIME .IS 14 WEEKS. 8-96, A. WAGNER **SLOW MOVING INVENTORY REPRICED PER SHAKUN 04/03**
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required