GE Healthcare · X-ray VascularInnova10502635026310501031050042
Detector lift won't move up or down.
Symptom
The Detector or II Lift does not drive up or down. When attempting to drive the II/Detector lift from the TSUI (smart handle or smart box) It does not drive up or down.n.
Error message
1050263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 50263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift Limit Switch 0 0 - Limit switch 1 problem (prd: BB) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 This error will always be preceeded by error 1050103 and 1050042 1050263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift Limit Switch 0 0 - Limit switch 1 problem (prd: BB) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 This error will always be preceeded by error 1050103 and 1050042 1050103 Pivot AXIS POWER WR GantryAxis No Motion Pivot AXIS POWER 1 0 - Power input from K3 problem (prd: BD) 1050042 Larm AXIS POWER WR GantryAxis No Motion Larm AXIS POWER 1 0 - Power input from K3 problem (prd: BD)
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.