GE Healthcare · MRExcite2220007
CoilID Light is Off or Dark with 2220007 The prescribed RF coil and detected RF coil do not match Due to SSM SRI Power S…
CoilID Light is Off or Dark with 2220007 The prescribed RF coil and detected RF coil do not match Due to SSM SRI Power Supply.
Symptom
CoilID Light is Off or Dark with 2220007 The prescribed RF coil and detected RF coil do not match 2220007 The prescribed RF coil and detected RF coil do not match. Upper coil connect status:0, Upper coil code:Null, Lower coil connect status:0, Lower coil code: Null, Rx coil name:HEAD, Rx coil code:bv523rifp0t9r4h3pgqceh64jh7d2n2d
Error message
2220007 The prescribed RF coil and detected RF coil do not match. See long description on reading/interpreting this type of error message Note: An example of this error message, with explanation, is provided below. Wed Mar 3 08:18:58 2004 Error: 2220007 Host: lx-mr3 Process: scn File: RxMgrDownload.m Line: 2074 The prescribed RF coil and detected RF coil do not match. 040303104912225 Upper coil connect status:0, Upper coil code:Null, Lower coil connect status:1, Lower coil code:q8dCUW0PD2EaETIplAp90PLrACM6CW38, Rx coil name:MRI 8HRKNRR PA, Rx coil code:q8dCUWOPD2EaETIpIAp9oPLrACM6CW38 NOTE: Upper coil connector status refers to connector plugged into upper port at "dog house" (i.e. head coil or Med' Adv' QUAD KNEE ("chimney") coil). Lower coil connect status refers to all PA coils / any coil using the lower port at the "dog house". Coil code should match that of what was detected (in this case the zeros were config'd as O and o (oh's - upper and lower case), and the number one following "ETIp" was an "I").Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- 2160200-9 ERBTEC #550014 PWR SUPPLY (3 BD) FRU ERBTEC #550014 PWR SUPPLY (3 BD) FRU 2160200-9: This FRU is also known as the "Integrated Power Supply Assembly" and consists of three boards each of which is also available separately as a FRU: The HV Power Supply Board (2160200-10), the Dock/Light Power Supply Board (2160200-11) and the Buck H-Bridge Power Supply Board (aka Buck Boost Power Supply 2160200-12). ERBTEC #550014 PWR SUPPLY (3 BD) FRU 2160200-9: This FRU is also known as the "Integrated Power Supply Assembly" and consists of three boards each of which is also available separately as a FRU: The HV Power Supply Board (2160200-10), the Dock/Light Power Supply Board (2160200-11) and the Buck H-Bridge Power Supply Board (aka Buck Boost Power Supply 2160200-12). Author: Pasi Vilkkila SME: Paul Lyman
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.