Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova

Innova, Unable to complete or failing detector bad pixel gain calibration TSG.

Innova, Unable to complete the detector bad pixel calibration.

Symptom

Innova, Unable to complete or failing detector bad pixel gain calibration TSG. . See LD for details on different scenarii that can occur. Innova, Unable to complete or failing detector bad pixel gain calibration Abort of BP calibration before starting computation X-ray abort is displayed 14% into the fifth exposure. Bad pixel calibration fails at 10% after the first exposure. the first step (offset) passes. the second step aborts after the first exposure. Acquisition does not start and is aborted after a time out of 4000 msecs. Cal fails Failed Results of BP calculation 1/ Segment density out of spec 2/ Bad pixel density out of spec

Error message

Bad Pixels calibration failed on Segment Density Bad Pixels calibration failed on Segment Density. See long description for further details. The system fails when running Bad Pixel Calibration with the following results displayed in the SUIF: Isolated pixels 44 PASS Small Clusters 10 PASS Medium Clusters 0 PASS 3x3 Clusters 0 PASS Large Clusters 0 PASS V Large Clusters 0 PASS Bad Lines 0.98 PASS Segment Density 0 FAIL <============ FAILED RESULT Bad Pixel Density 20 PASS There are no noticeable artefacts showing on clinical images, customer has not complained about any artefact issues. With the bad pixel correction and gain correction switched off in the RTAC (See Job card TSG-15 from Innova TSG), the resulting images show a black vertical line from half way down the image to the bottom edge, approx one third of the way from left hand edge of image.

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Component
Innova 2100IQ Detector with Part numbers Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-6-200, Rev# 1 and is provided for your reference: Innova 2100IQ; 5127984, 21 cm Apollo Detector Green (NEW installs) 5129033, 21 cm Apollo Detector Repair Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-6-200, Rev# 1 and is provided for your reference: Innova 2100IQ; 5127984, 21 cm Apollo Detector Green (NEW installs) 5129033, 21 cm Apollo Detector Repair
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues