Will not scan with 2248759 RF Amplifier Response Timeout Due to SRFD2 RF Amplifier.
Symptom
Unknown SRFDII Error Code 2254050 with RF Amplifier fault 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, and 90-96 On Excite systems running 11.0 software, we have seen error code 2254050 with various "RF Amplifier fault" codes such as 80, 81, 82, 83, 84, 85, 86, 87, 88, 89. However there is no other information in the error message and we can't find this error code in any troubleshooting document. What does error code 2254050 mean on Excite systems? PQR # 13099995. See Long Description for an example of this error message. On Excite systems running 11.0 software, we have seen error code 2254050 with various "RF Amplifier fault" codes such as 80, 81, 82, 83, 84, 85, 86, 87, 88, 89. However there is no other information in the error message and we can't find this error code in any troubleshooting document. What does error code 2254050 mean on Excite systems? PQR # 13099995 Tue Jan 9 16:08:43 2007 Error: 2254050 Host: lx-mr Process: NSP File: SCP:../RfNbMdsHWO.cpp Line: 2146 RF Amplifier fault 80.
Error message
2248761 RF Amplifier Error. The RF amplifier reset watchdog engaged See Long Description 2248761 NSP SCP: RF Amplifier Error. The RF amplifier reset watchdog engaged. This indicates either a microprocessor fault condition exists or a cold start is in progress. 2248759 RF Amplifier Response Timeout RF MDS peripheral to RF Amp/RF Interface link failure. 2248759 NSP SCP: RF amplifier response timeout. RF MDS peripheral - RF Amp/RF Interface link failure. Verify that the RF Amplifier or RF Interface is powered on and that the RF MDS peripheral is connected to the RF Amplifier or RF Interface. 2254050 RF Amplifier fault 80. Error: 2254050 Host: lx-mr Process: NSP File: SCP:../RfNbMdsHWO.cpp Line: 2146 RF Amplifier fault 80.
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- SecondOpinion SRFD2 1.5T Solid State RF Amplifier 2351573 See comments in Resolution Concept for second opinion requirements before ordering this part. SecondOpinion SRFD2 1.5T Solid State RF Amplifier 2351573
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.