GE Healthcare · X-ray VascularInnova1050143
INX100, Lost All Gantry axis's drive or NO movements
Symptom
INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor
Error message
1050143 DO (0x4B10 HW:0x0001 and US:0x8000), GantryAxis ANT CINEMATIC ERROR Pivot Debug: - ANTICOLLISION CINEMATIC ERROR (0x4B10 HW:0x0001 and US:0x8000), speed error on Pivot 1050143 DO GantryAxis ANT CINEMATIC ERROR Pivot Debug: - ANTICOLLISION CINEMATIC ERROR (0x4B10 HW:0x0001 and US:0x8000), speed error on Pivot HW (hardware) code Axis 0x0000 Larm axis 0x0001 Pivot axis 0x0002 ARC axis 0x0003 II (lift) axis 0x0008 table Longitudinal axis 0x0009 table Lateral axis 0x000A table Height axis 0x000B table Rotation axis US (user) code Axis 0x8000 Speed problem 0x4000 Position problem 1050143 DO GantryAxis ANT CINEMATIC ERROR Pivot Debug: - ANTICOLLISION CINEMATIC ERROR (0x4B10 HW:0x0001 and US:0x8000), speed error on Pivot This error is due to big variation detected on Positioner Position values. It can be due to a shortcut on cable, or a bad potentiometer or encoder. Recommended Action: The debug text column corresponding to this error contains important isolation information, according to the following tables. HW (hardware) code Axis 0x0000 Larm axis 0x0001 Pivot axis 0x0002 ARC axis 0x0003 II (lift) axis 0x0008 table Longitudinal axis 0x0009 table Lateral axis 0x000A table Height
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.