Omega, Unexpected table rotation or rotational Lock is not working.
Symptom
Omega, Unexpected table rotation or rotational Lock is not working. See FMI 12137 Omega IV and Omega V tables may experience an unexpected table rotation during patient transfer due to rotational table brakes slippage. FMI 12137 Dated 1/2010 Lost of voltage on lock will kept the on. Voltage is to remove the brake or hold of the lock. Omega IV and Omega V tables may experience an unexpected table rotation during patient transfer due to rotational table brakes slippage. Lost of voltage on lock will kept the on. Voltage is to remove the brake or hold of the lock. Table top rotation lock not holding. FMI 12137 Dated 1/2010, for all Omega 4 &5 DOC, DOC0683423, Rev:2 PURPOSE / HISTORY This FMI is generated to fix Complaint 13238255 (Master). Omega IV and Omega V tables may experience an unexpected table rotation during patient transfer due to rotational table brakes slippage. This event is most likely to occur when patient is transferring himself from the bed to the table, leading to a potential patient fall. Products labelling specifies that when loading and unloading the patient onto the table, table top should be maintained in order to ensure it does not move. The omega table rotation brakes need to comply to 2 contradictory specifications: 1) Brakes should be strong enough to hold table and avoid unexpected rotation when locked. 2) Brakes should be weak enough to slip allowing to disengage patient if a CPR required while power is off. Investigation showed that table rotation torque specs should be increased from 26.5 to 38.7 daN.m.
Applies to
- Models
- Advantx, Innova
- Product
- Advantx, LFX Advantx product line LFX Advantx product line Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $, Innova 2000 Service Pack FMI F4, HerSvcPack_2.02 HerSvcPack_2.02 DL Applications version 11.23.26 Ghost DL-1 "F" : 17.4 Ghost DL-1 "G" : 15.5 Ghost DL-2 : 16.4 Ghost DL-4 : NA DL : 11.23.26 DL Atlas Core : 3.1O-1 RTAC Atlas Core : 3.1O-2 IDC : 2.13 Calypso : 11.13_FMI_7 Calypso Uptime : 11.25_FMI Titan : H0.57 Pos. Motorola : 5.2Y3-2 Pos. Roadrunner : 5.0R
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.