ID134536 Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor.
Symptom
Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor. Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Monitor.
Error message
3602025 (FRT) or 3702025 (LAT) Jedi: Openload , Unbalanced , Phase Error During Rotation. Debug: jedi-error-code=104h or 105 JEDI Error Code: 0104H Openload Data Related to Error: 5 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY 3602025 (FRT) or 3702025 (LAT) Jedi: Openload , Unbalanced , Phase Error During Rotation. Debug: jedi-error-code=104h JEDI Error Code: 0104H Openload Data Related to Error: 5 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY May also be Jedi error code 0105H IH XRTechMgr acquisition JEDI Openload Unbalanced Phase error on Rotation 1 05 J EDI Error Code: 0105H Phases unbalanced Data Related to Error: 5 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND BY 212011882 04/02/2009 13:10 GMT This is a little different of an error. The resolutin was to Replace the Rotation board.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Innova Jedi Innova Jedi Innova Jedi
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.