GE Healthcare · X-ray VascularInnova360208637020863602035602035
Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.
Symptom
Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.
Error message
INX100, INX1X1: 3602086 (Frt) or 3702086 (Lat) Jedi: LVPS problem JEDI Error Code: 0xxxH INX100, INX1X1: 3602086 (Frt) or 3702086 (Lat) Jedi: LVPS problem JEDI Error Code: 0xxxH. See long description for further details on Jedi err code description. INX100, INX1X1: 3602086 (Frt) or 3702086 (Lat) Jedi: LVPS problem JEDI Error Code: 0xxxH. Standard format message is: 3602086 (3702086) DO XRTechMgr Front (Lat): Jedi: LVPS problem Debug: jedi-error-code=0xxxh JEDI Error Code: 0xxx H " Error Text " Data Related to Error: 153 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY Error code and error text associated: 0531H - LVPS 400: heater 0 +160V too high 0532H - LVPS 400: heater 0 +160V too low 0533H - LVPS 400: heater 1 +160V too high 0534H - LVPS 400: heater 1 +160V too low 0535H - LVPS 400: main inverter +17V too high 0536H - LVPS 400: main inverter +17V too low 0537H - LVPS 400: main inverter +26V too high 0538H - LVPS 400: main inverter +26V too low 0539H - LVPS 400: main inverter +160V too high 0540H - LVPS 400: main inverter +160V too low INX100: 3602035 Front: Jedi: Heater 1 detects curr
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- $ M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.