GE Healthcare · CT18370544533182104183714
Lightspeed 1.X - Octane
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 183705 Console Push Button Watchdog Timeout. See LD for more details Sat Nov 25 04:49:14 2006 Error: 183705 Host: STC Process: Console Pushbuttons File: cp_wdog.c 1.23 Line: 215 Function: No System Function Reported Scan: 44533/2/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 04:49:11:650 Log Series: 353 Console Push Button Watchdog Timeout. HW Error: Possible hardware problem. Error: 182104 Logging TIMEOUT for uuid 292. See long description for sample error message. Fri Feb 20 11:37:02 2009 Error: 182104 Host: STC Process: Master Exc Handler File: exm logging.c Line: 211 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 11:37:02:110 Log Series: 22 Logging TIMEOUT for uuid 292. Error: 183714 Hardware Rx Received While Console Pushbuttons Serial Link Is Down. HW/SW Error: Probable hardware, possible software, problem. See LD for Error Tue Jul 5 16:08:55 2005 Error: 183714 Suite: CT05 Host: STC Process: Console Pushbuttons File: cp in mail.c 1.56 Method: No Method Line: 722 Function: No System Function Reported Scan: 0/0/1 Type: Static Exception Level: Pri/Most Severe Time: 16:08:56:200 Log Series: 64 Hardware R
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-264806G2 AXIAL CONTROL BOARD ALLOWING .8 SEC See long description for details Part #: 46-264806G2 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL CONTROL BOARD ALLOWING .8 SEC FRU: Yes Status: Orderable Comments: OBSOLETE PART case 6763061 This part has been identified as obsolete and no short-term solution has been identified FE must identify and order a higher or lower level spare part as required Contact your support engineer on-line engineer or Parts ID team should you require support 212012173 05-23-07 FLS - FE ASSIT: MS6588 05/22/98 46-264806G2 = AXIAL BD FOR CTI& QXI SYSTEMS WITH 0.8 SEC SCANNING. THIS BOARD HAS THE PALS FOR 0.8 SECOND ROTATION. THE T3202KD = .8 SEC AXIAL BD. THE T3202BD =1.0 SEC AXIAL BD. THE ONLY DIFFERENCE BETWEEN THE T3202KD AND T3202BD ARE TWO PALS. THE T3202BD CAN BE UPGRADED TO THE T3202KD BY CHANGING PALS U211 AND U101. DO YOU STILL WANT TO ORDER THIS PART?
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required