LightSpeed 4.X - GRE
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 184158 Timeout on table elevation query. See long description for full error Mon Nov 3 06:09:02 2008 Error: 184158 Host: STC Process: Scan Control File: scScanDataQuery.c 1.29 Line: 396 Function: No System Function Reported Scan: 50331/8/15 Type: Axial Exception Level: Secondary Time: 06:08:55:430 Log Series: 803 Timeout on table elevation query. HW/SW Error: Possible hardware or software problem Error: 182003 HW/SW Error: Did not receive message from STC See long description Sat Mar 13 09:41:41 2010 Error: 182003 Host: STC Process: Local Exc Handler File: exl_verify_wdog.c Line: 134 Function: No System Function Reported Scan: 6789/2/0 Type: None/Unknown Exception Level: Secondary Time: 7089968 Log Series: 0 Local controller Notify Verification TIMEOUT for uuid 220. HW/SW Error: Did not receive message from STC. Will need a Hardware Reset. Error: 182104 Logging TIMEOUT for uuid 292. See long description for sample error message. Fri Feb 20 11:37:02 2009 Error: 182104 Host: STC Process: Master Exc Handler File: exm logging.c Line: 211 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 11:37:02:110 Log Series: 22 Logging TIME
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2224296-3 Artysen board for 1X/2X/3X/4X used in the ETC/STC/OBC See Long Description for FEMC information and board locations Part #: 2224296-3 Part Type: GP REPAIRABLES Part Weight: 1.09 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: VE-GE, 8MB, Artesyn CPU Bd FRU: Yes Status: Orderable Parts Offered as: Current : 2224296-3 Harvested : Not Available Exchange : Not Available Comments: ** FE ASSIST ** Repair operations has found that 68% of the time the Artesyn board (2224296-3) is returned for repair, it has No Defect Found. Check switch settings (212001261 2/12/09)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required