GE Healthcare · CTLightSpeed1821041119518241118480235462
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Table will not lower below 210 (+-5) mm as shown on Gantry Display. Table will move up and down above 210mm.
Error message
Error: 182104 Logging TIMEOUT for uuid 92 See long description for full sample error Mon Mar 17 03:55:29 2008 Error: 182104 Host: STC Process: Master Exc Handler File: exm logging.c Line: 228 Function: No System Function Reported Scan: 11195/2/0 Type: None/Unknown Exception Level: Sec/Soft Time: 03:54:54:905 Log Series: 119 Logging TIMEOUT for uuid 92. Error: 182411 Motion was prohibited by hardware Interference switches. See long Description for how to DECODE this error Fri Feb 24 21:59:29 2006 Error: 182411 Host: ETC Process: Elevation File: emcControl.c 1.23 11/13/92 Line: 170 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 21:59:20:810 Log Series: 66 HW/SW error: Motion was prohibited by hardware Interference switches. Hardware Inhibit Switches 0xc0dc Error: 184802 Communication Facility Error: 2103 Dest uuid: 0 Msg Code: 7021 See LD for complete error Fri Mar 10 10:50:32 2006 Error: 184802 Host: ETC Process: Table Controls File: tc_exec.c 1.27 1/15/96 Line: 219 Function: No System Function Reported Scan: 35462/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 10:50:32:880 Log Series: 267 Comm
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 See long description for details 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 Part #: 2372485 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: ETC INTERFACE W/ AZ60A FRU: Yes Status: Orderable Comments: FLS - ETC INTERFACE W/ AZ60A. ADDED PER PCN 220857. REPLACES P/N 2229871. USE UP EXISTING STK. MS20544 5/1/03. ONE USE LIGHTSPEED PLUS VC:611695-SCI, RAPID CITY, SD CONTROL PCB 46-264368G3
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.