Smart Handle replacement
Symptom
C-arc not moving Customer said the gantry motion did not work anymore. Then, he told that initial problem was located on the C-arc motion. He was unable to drive C-arc (motion starts then automatically stops). If L-arm at 0°, only C-arc motion is impacted whatever machine / anatomical mode selected on Smart handle / smart Box. if L-arm is moved to a position different from 0°, C-arc AND pivot motion will be impacted in ANATOMICAL mode. Customer said the gantry motion did not work anymore. Then, he told that initial problem was located on the C-arc motion. He was unable to drive C-arc (motion starts then automatically stops). If L-arm at 0°, only C-arc motion is impacted whatever machine / anatomical mode selected on Smart handle / smart Box. if L-arm is moved to a position different from 0°, C-arc AND Pivot motion will be impacted in ANATOMICAL mode.
Error message
4B07 with hardware 104 and user 0002 indicates rocker c arc control is defective. Attempt to calibrate rocker. If this fails replace smart handle. 4B07 with hardware 104 and user 0002 indicates rocker c arc control is defective. Attempt to calibrate rocker. If this fails replace smart handle.
Applies to
- Models
- Advantx, Innova
- Product
- Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx, LFX Advantx product line LFX Advantx product line
- Component
- smart handle smart handle smart handle one type of handle is: 5145783-2 FRU Smart handle Zenith_Unity 212000947 09/22/2010 10:28 GMT see vascular suport central site (@vascparts) for a cross refference of handles, boxes, and tssc's 212000947 04/09/2010 18:48 GMT Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.