GE Healthcare · MRExcite225008322501092245309162784722500822253851
Gradient Data Overrange Errors Due to STIF Board.
Symptom
Will Not Scan with Gradient Errors.
Error message
2250083 Y Axis Gradient Data Overrange Occurred. Error: 2250083 Host: CHCMR2 Process: NSP File: SCP:Grad Line: 3255 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: FSE-XL Coil: HD TRknee PA Scan: 2458/7 Y Axis Gradient Data Overrange Occurred.- 2250109 The GP is reporting a Gradient Clock Stop. The GP stopped receiving a gradient clock signal from the systems cabinet. 2245309 Gradient Diagnostic test has been aborted because GP detected a bad clock input 2245309 WCLAGEMR2MR diagCoord grad_lib.c 924 Diagnostic: Grad Frame/Clk Iteration: 25 of infinite Action: 1 Task ID: 0x3fc4380 Time: 1627847 Object: SCP Test Task Function: Gradient: N/A Gradient Diagnostic test has been aborted because GP detected a bad clock input.-> Extended error log: "Check placement of Clock and X,Y,Z data fibers between the STIF and GP (look for swapped fibers between clock and x/y/z data fibers)" 2245309 WCLAGEMR2MR diagCoord grad_lib.c 924 Diagnostic: Grad Frame/Clk Iteration: 25 of infinite Action: 1 Task ID: 0x3fc4380 Time: 1627847 Object: SCP Test Task Function: Gradient: N/A Gradient Diagnostic test has been aborted because GP detected a bad clock input.-> Extended error log:
Applies to
- Models
- Excite
- Product
- Excite HDe. For Hino HDe 14.0 and HDe 15.0 Software Systems only
- Software
- HDe 14.0 For Hino Excite HDe 14.0 systems only.
- Component
- 2280952-3 STIF Board See Long Description SRF TRF I/O or STIF 2280952 crosses up in FEMC to 2280952-3. Part Description is "STIF Assembly".
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.