Scan stops due to the high order shim power supply.
Symptom
Scan stops with error 2252755 & 2218537 Scan stops with error 2252755 & 2218537. Tue Jan 13 18:04:32 2009 2218537 mr3tscn MsaScanMgr.m3038 Arrêt acquisition. Scan Stopped due to error : The bore temperature sequence was not updated by the SCP within the 5 second interval. This indicates that the SCP is not monitoring the bore temperature during scan. Possible SCP functionality failure. Tue Jan 13 18:04:30 2009 2252755 6 mr3t NSPAGP:agp_drv.c 1647 Exception Class: Unknown Severity: UnknownFunction: Acquisition/Pulse Generation: Pulse GenerationPSD: FSE-XL Coil: HDCTL BOT Scan: 4021/3 The bore temperature sequence was not updated by the SCP within the 5 second interval. This indicates that the SCP is not monitoring the bore temperature during scan. Possible SCP functionality failure.
Error message
2252755 Scan stopped: The bore temperature sequence was not updated by the SCP See long description Tue Jan 13 18:04:30 2009 2252755 6 mr3t NSP AGP:agp_drv.c 1647 Exception Class: Unknown Severity: Unknown Function: Acquisition/Pulse Generation: Pulse Generation PSD: FSE-XL Coil: HDCTL BOT Scan: 4021/3 The bore temperature sequence was not updated by the SCP within the 5 second interval. This indicates that the SCP is not monitoring the bore temperature during scan. Possible SCP functionality failure. 2218537 Scan stopped: The bore temperature sequence was not updated by the SCP. See long description Tue Jan 13 18:04:32 2009 2218537 mr3t scn MsaScanMgr.m 3038 Arrêt acquisition. Scan Stopped due to error : The bore temperature sequence was not updated by the SCP within the 5 second interval. This indicates that the SCP is not monitoring the bore temperature during scan. Possible SCP functionality failure..
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.