ICN VRE Upgrade Tips for 14.0 M5A FMI 60753 and 15.0 M3.
Symptom
ICN VRE Upgrade Tips for 14.0 M5A FMI 60753 and 15.0 M3 See Long Description From SN DOC0555978 released on February 5, 2009 (see Attachment for the complete Service Note) Service Note is also available from this link: http://3.87.118.28/optec3/common/fmisn/DOC0555978.pdf To view the most recent appropriate and detailed documentation, click to go to MR Service Documentation. ICN Issues in the Field PROBLEM : A few issues have been reported in the field regarding the functionality of the ICNs. Please read below, as the effectivity for each issue may be different. SOLUTION : This service note is intended to highlight the following issues and provide a valid workaround: 1. INFINIBAND FIRMWARE ISSUE – Applicable to 14M5A & 15.0 M3 MR systems with Dedicated Computing ICNs. Effectivity: 1.5T & 3.0T Signa HDx 14M5A & 15.0 M3 MR systems with Dedicated Computing ICNs. Problem: It has been reported that one or more of the Dedicated Computing (DC) ICNs may have an obsolete Infiniband firmware version. This problem has caused symptoms after a software load or after a VRE configuration. This problem does NOT apply if all ICN computers have Infiniband firmware version 3.4.0 or greater. Symptoms: Scans stop or fail to deliver the expected number of images. The root cause is degraded Infiniband performance. Some sites may only see some protocols affected. In most cases, 3-plane localizers with multiple slices per plane generate errors. The following error message may be seen: Thu Jan 15 16:50:49 2009 2218537 1 MsaScanMgr.m 3038 Scan stopped, Scan Stopped due to error : SCT Interface Error. No source was detected for a SCT command Additional “ Infiniband backlog too large…scan stopped ” messages are seen as well in the APS window. 2. DEDICATED COMPUTING ICN HARD DISK FAILURE – Applicable to HDx 14M5A, and HDxT 15.0 M3 MR systems with Dedicated Computing ICNs. Effectivity: 1.5T & 3.0T Signa HDx 14M5A, and HDxT 15.0 M3 MR systems with Dedicated Computing ICNs. Problem: VRE configuration fails after software load. Symptoms: The ICN product configuration has two hard disks and is checked for validity at the time of VRE configuration of 14M5A or 15.0 M3 software. This check for valid product configuration did not exist in the earlier 14M5 software. The install fails with an “ unknown board type found in ICN system ” error. The VRE Install log file (/usr/local/bin/install/log/VRE_Install.log), will contain the following message if it did not detect the hard disks on the ICN: Unknown board type found in ICN system. DRIVES: Found, tconfig{DRIVES} drives 3. SUN ICNs NOT RECOGNIZED AT SYSTEM POWER-UP – Applicable to HDx 14M5A, HDxT 15.0, and MR750 20.0 MR systems with SUN ICNs. Effectivity: 1.5T & 3.0T Signa HDx 14M5A, HDxT 15.0, and MR750 20.0 MR systems with SUN ICNs. Problem: During system power-up, ICN(s) fail to boot up with the system. Symptoms: TPS reset will fail at power-up because the ICN(s) are NOT initialized properly. 4. 14M5A SERVICE PACK 3 PRE-SCAN FAILURES – Applicable to HDx 14M5A Service Pack 3 MR systems. Effectivity: 1.5T & 3.0T Signa HDx 14M5A Service Pack 3 MR systems. Problem: Pre-scan fails, TPS reset is required.During Autoshim pass of pre-scan, customer receives the syslog message: Sat Oct 4 11:32:20 2008 Error: 2255482 Host: b3 Process: LxMxConsumer File: base/MxServer.cpp Line: 836 Server Name: DPx Unknown server software error occurred. TPS reset may be required. Further errors, such as BAM Check Packet failed to reach the TPS , may follow. Symptoms: The problem is most frequently seen on the localizer (with autoshim) of a next exam, when the previous exam runs a large multiphase prescription, such as Vibrant with Multiphase variable delay (aka. Dynaplan). Other conditions are possible, but have not been reported.
Error message
2248371 SCT Interface Error. No timestamp was detected for a SCT command. Tue Mar 23 08:08:27 2004 Error: 2248371 Host: IRIS Process: NSP File: SCP:SctPxProxy Line: 538 SCT Interface Error. No timestamp was detected for a SCT command. Tue Mar 23 08:09:31 2004 Error: 2248370 Host: IRIS Process: NSP File: SCP:SctPxProxy Line: 653 SCT Interface Error. No source was detected for a SCT command.
Unknown board type found in ICN system. DRIVES: Found, tconfig{DRIVES} drives See Long Description Message is found in the VRE Install log file (/usr/local/bin/install/log/VRE_Install.log).
2255482 Unknown server software error occurred. TPS reset may be required. See Long Description Error: 2255482Host: b3 Process: LxMxConsumerFile: base/MxServer.cpp Line: 836Server Name: DPx Unknown server software error occurred. TPS reset may be required.
2248370 SCT Interface Error. No source was detected for a SCT command. See Long Description 2248370 mcoamr1 NSP SCP:SctPxProxy 833 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Gradient Echo Coil: QUADANKLE Scan: 5207/1 SCT Interface Error. No source was detected for a SCT command
Infiniband backlog too large…scaApplies to
- Models
- Excite, Signa
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 M5 Excite HDx HDi Platforms only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.