Scans Stop or Pause with Autovoice Error 2265211 and or 2265215 Logged.
Symptom
Scans Stop or Pause with Autovoice Error 2265211 and or 2265215 Logged See Long Description Scans stop or pause with the autovoice error(s) shown below logged. You may see one or both errors logged. You may not necessarily see both errors every time it happens or at all sites. iTrak # 13240619. Tue Jan 27 11:25:29 2009 Error: 2265211 Host: eiamrlx Process: NSP File: SCP:AutovoiceHostHWO Line: 1633 Exception Class: Unknown Severity: Unknown Function: Host: AutoVoice PSD: FRFSE-XL Coil: KNEEPA Scan: 8832/2 Autovoice Communication Error. Host Autovoice Player failed to respond to a packet from the SCP. Packet opcode waiting for a response: OP_AUTOVOICE_DU -------------------------------------------------------------------------------------------------------- Tue Jan 27 11:25:29 2009 Error: 2265215 Host: eiamrlx Process: NSP File: SCP:AutovoiceHostHWO Line: 638 Exception Class: Unknown Severity: Unknown Function: Host: AutoVoice PSD: FRFSE-XL Coil: KNEEPA Scan: 8832/2 Autovoice Communication Error. SCP failed to receive a packet from Host Autovoice Player. SCP is attempting to recover the link
Error message
2265211 Autovoice Communication Error. Host Autovoice Player failed to respond to a packet from the SCP. Packet opcode waiting for a response: OP_AUTOVOICE_WA See Long Description Error: 2265211 Host: MR04 Process: NSP File: SCP:AutovoiceHostHWO Line: 1633 Exception Class: Unknown Severity: Unknown Function: Host : AutoVoice PSD: FRFSE-XL Coil: 7breast Rt MRI Scan: 6144/5 Autovoice Communication Error. Host Autovoice Player failed to respond to a packet from the SCP. Packet opcode waiting for a response: OP_AUTOVOICE_WA 2265215 Autovoice Communication Error. SCP failed to receive a packet from Host Autovoice Player. SCP is attempting to recover the link. See Long Description Error: 2265215 Host: eiamrlx Process: NSP File: SCP:AutovoiceHostHWO Line: 638 Exception Class: Unknown Severity: Unknown Function: Host: AutoVoice PSD: FRFSE-XL Coil: KNEEPA Scan: 8832/2 Autovoice Communication Error. SCP failed to receive a packet from Host Autovoice Player. SCP is attempting to recover the link.
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 M5 Excite HDx HDi Platforms only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.