Innova Modality Worklist Query fails on an Innova system from a HeartLab Worklist Provider.
Innova Modality Worklist Query fails
Symptom
Innova Modality Worklist Query fails on an Innova system from a HeartLab Worklist Provider. Modality Worklist Query fails on an Innova system from a Worklist Provider
Error message
2800036 Software problem during networking to archiving station: Innova 2800036 Software problem during networking DO XRSubSysMgrDL Network Transfert Software Problem 1 0 JobID:11403379, DJRNWLogger.cxx 68 2800036 Software problem during networking DO XRSubSysMgrDL Network Transfer Software Problem 1 0 JobID:11403379, DJRNWLogger.cxx 68 Innova: mwlServer.log reports DJR - root error= 4112; final Error=1004 when attempting to establish connection with the broker Innova: mwlServer.log reports DJR - root error= 4112; final Error=1004 when attempting to establish connection with the broker. F0=DJR - root error= 4112; final Error=1004; Message= MC Open Associati on F0=Attempting to establish connection: AEtitle(xxxxxxx), IPaddr(xx.xx.xx.xx), Innova: 2800175 Worklist query failure Debug: Association timeout 2800175 DO XRSubSysMgrDL Worklist query failure Debug: Association timeout, 1207 : BROWSER_WL_QUERY_FAILED The Innova is unable to open an Association with the Broker.
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.