The Cables Between the Magnet Monitor 3, Water Sensor Assembly and Compressor are disconnected. lcci2 alarm I2 WaterTemp…
The Cables Between the Magnet Monitor 3, Water Sensor Assembly and Compressor are disconnected. lcci2 alarm I2 WaterTemp Low.
Symptom
lcci2 alarm I2 WaterTemp Low. lcci2 alarm I2 WaterTemp Low, Water Temperature is lower than the low alarm limit setting on the Magnet Monitor 3.
Error message
Magnet Monitor 3 Error Code 05, Water flow for compressor 1 too low. Troubleshoot Low Flow condition. Check Cable and flow sensor. Magnet Monitor 3 Error Code 05, Water flow for compressor 1 too low. Troubleshoot Low Flow condition. Check Cable and flow sensor. LCCI2 ALARM I2 WATERTEMP LOW. LCCI2 ALARM I2 WATERTEMP LOW, the Water Temperature is lower than the low limit alarm setting on the Magnet Monitor 3. Magnet Monitor 3 Error Code 125, No 24v supply from compressor 1. Verify compressor is turned on. Verify compressor cable connected to MagMon3. Magnet Monitor 3 Error Code 125, No 24v supply from compressor 1. Verify compressor is turned on. Verify compressor cable connected to MagMon3. Magnet Monitor 3 Compressor Code 20, Compressor Powered Off or Cable is Disconnected No 24 Volts. Magnet Monitor 3 Error Code 07, Water temp for compressor 1 too cold. Check sensor and cables, actual water temp. Magnet Monitor 3 Error Code 07, Water temp for compressor 1 too cold. Check sensor and cables, actual water temp.
Applies to
- Product
- Magnet Monitor 3. Magnet Monitor 3 Magnet Monitor 3
- Software
- Magnet Monitor 3 Revision 1.56. Magnet Monitor 3 revision 1.56, distributed to sites with Connectivity automatically post FMI 60755 release on 6/23/2008. See Long Description for Fixes and Notes. Magnet Monitor 3 Revision 1.56 Software (formerly known as 1.55). Fixes New magnet type selection page with menus for both compressors. New remote commands to change the compressor selections. New uploaded properties to show the current compressor selections. A fix to the satellite interface so MM3 doesn't lose the sat link if it gets a malformed entitlement message. Changed configuration files so ABM and BOM magnets with DT500 sensors use the correct lookup tables. Disabled alarms actually won't generate alarms. The net mask no longer has to be entered with extra zeros (i.e. - 255.0.0.0 is now good enough instead of 255.000.000.000). The "Show Digital IO" web page shows all compressor types correctly - no more messages saying that Leybolds are inverted. New alarm limits for ABM and BOM for 2nd_stage_shield (is now 10K to 25K, was previously 3.5K to 10K). Changed Master Interval to 720 minutes for LCC and Non-Zero boil off magnets and 360 minutes for HFOs to reduce dispatch volume. NOTES •Software will be downloaded to all communicating sites except satellite modems. •Currently there is no CD that is orderable as a FRU for sites that do not have communication or have a satellite modem so that the software can be manually updated.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.