GE Healthcare · X-ray VascularInnovaAdvantx1050166501045021050105
advantx error 4AB5 - collision detection problem, please call service.
advantx error 4AB5 - collision detection problem, please call service. gantry is moving slow.
Symptom
advantx error 4AB5 - collision detection problem, please call service. gantry is moving slow. Advantx error 4AB5 - collision detection problem, please call service. Gantry is moving slow.
Error message
error Code = 1050166:Aborts Bolus and 3D acquisition.:error Text = DETECTOR BUMP SENSOR PROBLEM, debug Text = - DETECTOR COLLISION DETECTION PROBLEM during MP_DiagnosticBumpers (T:0x4AB5 H:0x4 U:0x2), recovery Class = WR, major Function /= GantryAxis System impact: Full gantry motion. Aborts Bolus and 3D acquisition. Displayed message : "Detector collision detection error. Continue with care or call Service." Or since Unity 3D M4 : "Detector collision sensor error. Press Detector front plate to re-init." error Code = 50104, HW=4 for the Detector Faceplate COLLISION error Text = POS : COLLISION DETECTION PROBLEM, debug Text += pos-error=4AB5, hw-status=0004, recovery Class /= WR, major Function /= VAS / POS System impact: Message displayed on monitors and BIP on TSSC every 30 seconds. Full gantry motion. Displayed message : "Collision detection failure, continue with care; Otherwise call Service" The Hardware code tells whether the problem is located on the Detector or on the Tube side: HW=4 for the Detector and HW=10 for the Tube Check the anti collision sensors on the Detector or tube. Touch the collision sensor margin on one side to re-balance the collision sensors. Touch the co
Applies to
- Models
- Innova, Advantx
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.