INJECTION FAILED X-RAY ABORTED; during a run or run-off after the mask image.
Symptom
INNOVA: INJECTION FAILED X-RAY ABORTED; during a DSA aquisition or run-off after the mask image. The injector has failed to inject. The Innova aborts X-ray during a DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested. The Innova aborts X-ray during DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested.
Error message
1050161 Unexpected Injection 1050161 UNEXPECTED INJECTION AR Injector Unexpected injection UNEXPECTED_INJECTION 1 0 - UNEXPECTED INJECTION OCCURED (4A72), injector injecting and the injector is inhbited Z:/heroic/injlayer.c 359 is logged in the error log 1050161 UNEXPECTED INJECTION AR Injector Unexpected injection UNEXPECTED_INJECTION 1 0 - UNEXPECTED INJECTION OCCURED (4A72), injector injecting and the injector is inhbited Z:/heroic/injlayer.c 359
Applies to
- Models
- Innova, Advantx
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- Innova, Unity 3D M4 SP3.1, Unity 3D M4 SP3.1, DL Release : UNITY_M4_FMI_4.21 Ghost DL : 21.24.2 DL : DL_Unity_4.21.5 DL Atlas Core : 4.2-8_6 RTAC Atlas Core : 4.2-8_6 IDC : 5.31 Calypso : 4.42 Calypso Uptime : CLYUPT.UNITY_4.21 Positioner : RR POS LBY 1.4.4U_19 Jedi : P636BF1
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.