GE Healthcare · CTBrightSpeedVCT2601110275139591
BrightSpeed 4/8/16 slice HPower Scanner Elite-16, Edge-8, Excel-4
Symptom
Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"
Error message
Error: 260111027 Gantry Control Button is non-functional See long description for full error Fri Oct 19 09:48:15 2007 Error: 260111027 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 5817 Fri Oct 19 09:48:15 2007 Host : Table Gantry Processor Ermes # : 260111027 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 5817 Function : OPERATOR INPUT/OUTPUT : Gantry Operator Interface Scan Type : None/Unknown Scan: 0/0/0 Gantry Control Alignment Light button is non-functional. Node Id: 4, Board Number: 5139591, Serial Number: 5184. This error number could be any of the buttons on the Control Panel. The error number is the same, but the verbage for each button is different.
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required