GE Healthcare · X-ray VascularInnovaAdvantx40000544000048
The Advantx Console is Blank on boot of the system.
Symptom
The Advantx Console is Blank on boot of the system. The console green power light is on, but the system appears to have not booted and the console has no display. The Advantx Console is blank on boot of the system. The console green power light is on, but the system appears to have not booted and the console has no display.
Error message
IN2K: Ping Test from Digital Leader to Titan Kernal Fails Ping Test from Digital Leader to Titan Kernal Fails. The Ping from the Digital Leader (DL) to the Titan fails. Attempt to ping the Titan Kernal from the DL. Open a command window and Ping 165.100.10.3. If The system reports "request timed out", The Ping to the Titan Kernal has failed IN2K: ECM has a PRD code of 72H on boot of the system. This indicates the ECM can not communicate with with the ASC or that the ASC is off line. Softstart will be off as a result. ECM has a PRD code of 72H on boot of the system. This indicates the ECM can not communicate with the ASC or that the ASC is off line. Softstart will be off as a result. 4000054 XRTitan connect call failed 4000054 XRTitan connect call failed: Component(s)_ETHERNET_Communication Root Cause : Component(s) - Ethernet Communication. This error is due to time out on Ethernet Communication with Titan subsystem. 4000048 could not send packet Component(s)_ETHERNET_Communication 4000048 : Recommended Actions: Root Cause : Component(s) - Ethernet Communication. This error is due to time out on Ethernet Communication. Recommended Actions: ping -t RTAC and Titan (165.100.10.2 an
Applies to
- Models
- Innova, Advantx
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.