Magnet Monitor 3 was not placed into Service Mode. lcci2 alarm I2 Comp No 24 volts.

Symptom

lcci2 alarm I2 Comp No 24 volts. lcci2 alarm I2 Comp No 24 volts, the compressor has lost 3-phase power and / or is turned off per the Magnet Monitor 3.

Error message

lcci2 alarm I2 Comp No 24 volts. lcci2 alarm I2 Comp No 24 volts, the compressor has lost 3-phase power and / or is turned off per the Magnet Monitor 3.

Magnet Monitor 3 Error Code 025, Vessel Pressure Too High. Check compressors. Check coldhead. Magnet Monitor 3 Error Code 025, Vessel Pressure Too High. Check compressors. Check coldhead.

Magnet Monitor 3 Error Code 05, Water flow for compressor 1 too low. Troubleshoot Low Flow condition. Check Cable and flow sensor. Magnet Monitor 3 Error Code 05, Water flow for compressor 1 too low. Troubleshoot Low Flow condition. Check Cable and flow sensor.

Magnet Monitor 3 Compressor Code 121, Compressor 1 is not running. Check compressor look for other compressor errors. Reference Temp, Pressure and Troubleshooting guide in the Functional Check section in the magnet manual. Check cable connections. Magnet Monitor 3 Compressor Code 121, Compressor 1 is not running. Check compressor look for other compressor errors. Reference Temp, Pressure and Troubleshooting guide in the Functional Check section in the magnet manual. Check cable connections.

Applies to

Product
Magnet Monitor 3. Magnet Monitor 3 Magnet Monitor 3
Software
Magnet Monitor 3 Revision 1.56. Magnet Monitor 3 revision 1.56, distributed to sites with Connectivity automatically post FMI 60755 release on 6/23/2008. See Long Description for Fixes and Notes. Magnet Monitor 3 Revision 1.56 Software (formerly known as 1.55). Fixes New magnet type selection page with menus for both compressors. New remote commands to change the compressor selections. New uploaded properties to show the current compressor selections. A fix to the satellite interface so MM3 doesn't lose the sat link if it gets a malformed entitlement message. Changed configuration files so ABM and BOM magnets with DT500 sensors use the correct lookup tables. Disabled alarms actually won't generate alarms. The net mask no longer has to be entered with extra zeros (i.e. - 255.0.0.0 is now good enough instead of 255.000.000.000). The "Show Digital IO" web page shows all compressor types correctly - no more messages saying that Leybolds are inverted. New alarm limits for ABM and BOM for 2nd_stage_shield (is now 10K to 25K, was previously 3.5K to 10K). Changed Master Interval to 720 minutes for LCC and Non-Zero boil off magnets and 360 minutes for HFOs to reduce dispatch volume. NOTES •Software will be downloaded to all communicating sites except satellite modems. •Currently there is no CD that is orderable as a FRU for sites that do not have communication or have a satellite modem so that the software can be manually updated.
Component
2333825 Water Flow Sensor Assembly. The part number for the new water flow (turbine) / temperature meter for Magnet Monitor is 2333825. The part number for the new water flow (turbine) / temperature meter for Magnet Monitor is 2333825.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required