No exposure fluoro or acquisition. xray starts for 1-2 seconds then aborts with error message. no images are acquired
Symptom
IN2K: No exposure fluoro or acquisition. xray starts for 1-2 seconds then aborts with error message. no images are acquired IN2K: No exposure fluoro or acquisition. xray starts for 1-2 seconds then aborts with error message. no images are acquired. Tube warm up is OK.
Error message
IN2K: Advantx error 4F35 followed by 4F2D and SUIF error 1600010 followed by 1610006 followed by 810006 IN2K: Advantx error 4F35 and 4F2D (Xray Aborted - Restart Xray - If problem persists, call service) SUIF error 1600010 (ImProc compares a different frame number between CF last notification and last image received on fiber link. 1 to 6 images may h. Debug: XRImProc did not received any DL frame during the last 1000msecs ) followed by 1610006 (Stop sequence timed out) followed by 810006 (Stop sequence timed out) Advantx error 4F35 and 4F2D (Xray Aborted - Restart Xray - If problem persists, call service) SUIF error 1600010 (ImProc compares a different frame number between CF last notification and last image received on fiber link. 1 to 6 images may h. Debug: XRImProc did not received any DL frame during the last 1000msecs ) followed by 1610006 (Stop sequence timed out) followed by 810006 (Stop sequence timed out)
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- FCIB board 5189435 FCIB board FRU number 5189435 FCIB board FRU number 5189435
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.