119244 Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
INX100: 3602069 Jedi: Spit or kV instability warning JEDI Error Code: 0324H Tube spit - spit cathode (yes) 3602069 Jedi: Spit or kV instability warning JEDI Error Code: 0324H Tube spit (all kV drop/regul errors) Spit Info: spit anode (no) - spit cathode (yes) - spit both (no) - kV_regul (no) Tube 1 70C: OK, Tube 40C: OK, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status:OK
Applies to
- Models
- Innova
- Product
- X Innova 4100 X Do not use---------4100 systems 4100 systems
- Software
- $Bolus M4++ Bolus_M4_1.25.FMI 12089 DL release : DL_LBYBOLUSM4_11.1.060210 Ghost DL-2 : NA Ghost DL-3 : 18.8 Ghost DL-5 : 20.6 DL : DL_LBYBOLUSM4_11.1.060210 DL Atlas Core : 3.1.R RTAC Atlas Core : 3.1.R IDC : 4.5.6 Calypso : 2.22 Calypso Uptime : BOLUS1.25 Positioner : 1.2.24B_IS6.6 Jedi : B6.30BFD
- Component
- Ulysses MX160 X-Ray Tube Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload) Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.