GE Healthcare · X-ray VascularInnova3602036360204136020193602087
Fluoro stopped intermittently, released the foot pedal then pressed it again could resume the fluoro
Symptom
Fluoro stopped intermittently, released the foot pedal then pressed it again could resume the fluoro at most the occasions. Fluoro stoped intermittently, released the foot pedal then pressed it again could resume the fluoro
Error message
3602036 Jedi: Power module problem JEDI Error Code: 0314H ILR current timeout 3602036 Jedi: Power module problem AR XRTechMgr acquisition JEDI_Power_Module_Problem 1 0 JEDI Error Code: 0314H ILR current timeout Data Related to Error: 0 Tube 1 70C: OK 3602036 Jedi Power Module Problem: AR. Also 3602041, 3602019, 3602087. 3602036: Jedi Power Module Problem: AR. JEDI Error Code: 0313H ILR max current detected Data Related to Error: 0 Tube 1 70C: OK 3602041: Jedi: kV problem detected: AR. JEDI Error Code: 0310H kV max detected Data Related to Error: 0 Tube 1 70C: OK 3602019: Bad kV Detected: DO. [XRTechMgr::notifyGeneratorFinalExposureParameters] numberOfTubeSpits=1 below the maxNumberOfTubeSpits=2 after 38 frames 3602087: Jedi: Tube spits error details: DO. [XRTechMgr::notifyGeneratorFinalExposureParameters] nu Name: 3602036 Jedi Power Module Problem: AR. Also 3602041, 3602019, 3602087. Clicking noise coming from XRT when exposure is attempted. 3602036: Jedi Power Module Problem: AR. JEDI Error Code: 0313H ILR max current detected Data Related to Error: 0 Tube 1 70C: OK 3602041: Jedi: kV problem detected: AR. JEDI Error Code: 0310H kV max detected Data Related to Error: 0 Tube 1 70C:
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Innova Jedi Innova Jedi Innova Jedi
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.