GE Healthcare · X-ray VascularInnova120020436020122002053800341360200563022
Communication Failure: Retry and if problem persists Reset System is displayed on the Innova Monitor.
Communication Failure
Symptom
Communication Failure: Retry and if problem persists Reset System is displayed on the Innova Monitor. Heat units 0 Communication Failure: Retry and if problem persists Reset System is displayed on the Innova Monitor. Xray is inhibited. Jedi issue, Heat units zero
Error message
1200204 ERR_RTBUS_LINK: XXX # missing x-ray pulses in XXX# msecs 1200204 ERR_RTBUS_LINK AR XRImDet AcquisitionMonitoringCheck Component(s)_RT_Bus_Communication 1 0 [ImageAcquisitionMonitoring] 2 missing x-ray pulses in 202 msecs img_acq_monitoring.cpp 444 3602012 Heat units (zero 0), Generator Communication failed: AR: Component(s)_RTAC_Jedi_link: Timeout during the power-up of the generator Xray aborted by 3602012 Generator communication failed Debug:timeout when configuring the generator. This error may be followed by mulitple other errors 3800341unable to start the exposure sequence when the generator is not configured, 200205 Unexpected sequencing, 3800341Thermal log - Prediction result not available or out of range Xray aborted by 3602012 Generator communication failed Debug :timeout when configuring the generator. This error may followed by mulitple other errors 3800341 unable to start the exposure sequence when the generator is not configured, 200205 Unexpected sequencing, 3800341Thermal log - Prediction result not available or out of range Also since there is no generator communication, the system should display Xray not Available, and the Heat units for the tube will be 0
Applies to
- Models
- Innova
- Product
- X Innova 4100 X Do not use---------4100 systems 4100 systems
- Software
- Innova, Unity 3D M4 SP3.1, Unity 3D M4 SP3.1, DL Release : UNITY_M4_FMI_4.21 Ghost DL : 21.24.2 DL : DL_Unity_4.21.5 DL Atlas Core : 4.2-8_6 RTAC Atlas Core : 4.2-8_6 IDC : 5.31 Calypso : 4.42 Calypso Uptime : CLYUPT.UNITY_4.21 Positioner : RR POS LBY 1.4.4U_19 Jedi : P636BF1
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.