GE Healthcare · X-ray VascularInnovaAdvantx600501501285012450125600104
The TSSC has an error code flashing in the Mag Mode and Auto Positioner.
Symptom
The TSSC has an error code flashing in the Mag Mode and Auto Positioner. Customer thought that FOV of detector was changing The TSSC has an error code flashing in the Mag Mode and Auto Positioner. The customer may think the FOV on TSSC was changing values by itself, while the FOV is displaying error code
Error message
600501 Collimator power failure; wait automatic recover Collimator Power Failure 600501 Collimator power failure; wait automatic recover error Code = 50128, error Text = POS Capacitive Sensor Board failure, debug Text += pos-error=4ACD, recovery Class = WR, major Function /= LC Gantry System impact: Degraded gantry motion. Displayed message : "Positioner failure - Reset system; if problem persists, call service". error Code = 50124, error Text = POS TSUI: TSSC+ error, debug Text += pos-error=4AC9, hw-status=0044, usr-status=0000, recovery Class = DO, major Function /= LC Gantry System impact: No X-ray, no gantry motion during 1 minute. Displayed message : None. 50125 POS : TSUI: SMB OR SMH ERROR 4ACA HW 00A5 User 0000 (SH master - Permanent enable: GANTRY MOTION ENABLE (c-arc & pivot)) TSUI: SMB OR SMH ERROR DO POS 0 0 HWStatus=00CA User=0000 0001 4ACA SH slave - Joystick motion: GANTRY MOTION (c-arc & pivot) 0x0010 Master TSSC - coherence box problem 0x0011 Master TSSC - satellite missing: Collimator joystick – II1 0x0012 Master TSSC - satellite missing: Contour filters joystick – II3 0x0013 Master TSSC - satellite missing: Autopos joystick – II4 0x0014 Master TSSC - keyboard m
Applies to
- Models
- Innova, Advantx
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.