Bolus would set up and perform the mask exposures.
Symptom
INX100: Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort.. Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort. # 2. Issue: The Innova aborts at the beginning of the Mask run with error 1200021, TRIG received while no PRETRIG has been received yet! LastFrameId=0, on the first Bolus chase of the day after system power off Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort. #2 issue, The Innova aborts at the beginning of the Mask run with error 1200021, TRIG received while no PRETRIG has been received yet! LastFrameId=0, on the first Bolus chase of the day after system power off
Error message
INX100: 1090011 TABLE WARNING: Axis over current during Dynamic Procedure WR Table 0 TBL AXIS OVER CURRENT 1 0 [XRImChainPos::logPosSymbolicError] Reporting the Motion Control error for GantryMotionControlError XRPAtlasLogger.cpp 156 1090011 TABLE WARNING: Axis over current during Dynamic Procedure WR Table 0 TBL AXIS OVER CURRENT 1 0 [XRImChainPos::logPosSymbolicError] Reporting the Motion Control error for GantryMotionControlError XRPAtlasLogger.cpp 156 May be followed by errors 2210001 Generic SW error for positioner subsystem 1050181 TBL AXIS OVER CURRENT 1000028 Software Debug bad data 2210001 Generic SW error TableControlManager::timerExpiredStampedPositions 200205 Unexpected sequencing Problem during STOP SEQ phase unexpected actor INX100: 2210001 Generic SW error for positioner subsystem: Table Bolus Phase Aborted Without RTAC Request Abort requested by positionner 2210001 Generic SW error for positioner subsystem AR XRPatPos control Software Problem 1 1 [XRPatPos::tableBolusPhaseAbortedWithoutRTACRequest] Abort requested by positionner XRPAtlasLogger.cpp 156 9 INX100: 1050181 TBL AXIS OVER CURRENT Table: Over current error. Hard over current. Motion halted. 1050181 TBL A
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.