GE Healthcare · X-ray VascularInnovaAdvantx501236004650125
Positioner TSSC or Smart handle/box.
113749 Positioner TSSC.
Symptom
Positioner TSSC or Smart handle/box. A permanent validation or an error has been found on TSSC by PIB. Positioner TSSC. A permanent validation or an error has been found on TSSC by PIB. Positioner TSSC or Smart handle/box. A permanent validation or an error has been found on TSSC by PIB.
Error message
error Code = 50123, error Text = POS TSUI: Permanent validation, debug Text += pos-error=4AC8, recovery Class = WR, major Function /= LC Gantry System impact: Permanent enable. Displayed message : "Smart handle problem. Please call service.". error Code = 60046, error Text = POS : SMART HANDLE CONTROL PROBLEM. CHECK IT OR CALL SERVICE, debug Text += pos-error=4B07, recovery Class = WR, major Function /= LC Gantry System impact: Permanent enable. Displayed message : "Smart handle problem. Please call service.". error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry HW A6 = SH master - Permanent enable: TABLE DRIVING ENABLE (longitudinal & up/down) System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, h
Applies to
- Models
- Innova, Advantx
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.