GE Healthcare · MRExciteDiscovery2218527222435822180622217995
Images Reconstructed but not Listed in the Browser, Only Displayed in Auto viewer.
Corrupt Image Database.
Symptom
Images Reconstructed but not Listed in the Browser, Only Displayed in Auto viewer. See Long Desc. Caller had images in Auto Viewer but not in Browser. Caller had scanned several series since but had turned off Autoview prior to scanning the additional new series. When Autoview is turned off, it will hold onto the last images that were scanned with it turned on.
Error message
2021 mkdir failed /export/home1/sdc_image_pool/reserved/IMSse2g893Y No space left on device 2218527 Scanning has stopped. Image file creation unsuccessful. Please try again. Error: 2218527 Host: UPCH-MR Process: scn File: MsaScanOpsScrn.m Line: 733 Scanning has stopped. Image file creation unsuccessful. Please try again. 2224358 Unable to open image file 2224358 lx-mr TIR update_image_header.c 223 Unable to open image file /export/home1/sdc_image_pool/reserved/IMSseSAA a000V5/8407.2.1.36. Errno = 2 2218062 Unable to add image path/header to tuple list Thu Oct 9 11:00:07 2003 Error: 2218062 Host: lx-mr Process: TIR File: ImageInstall.cc Line: 416 Unable to add image path/header to tuple list 2217995 Image file allocation failed. Please recover space for X images. See Long Prescription Error: 2217995 Host: UPCH-MR Process: ifcc File: IfccScan.cc Line: 3529 Image file allocation failed. Please recover space for 21 images.
Applies to
- Models
- Excite, Discovery
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.