Innova: Positioner error.

Positioner error.

Symptom

Innova: Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited, Lost All Gantry axis's drive or NO movements. Omega table elevation will not drive down. Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited, Lost All Gantry axis's drive or NO movements. Omega table elevation will not drive down. Lift failure, dose is minimized, call service

Error message

INX100: 1050297 POS EVENT LOG - Emergency backout has been pressed or released Typically No intervention needed. The customer has pressed and released the emergency backout button. If the errors are logged repeated, may be a button issue or relay issue. INX100: 1050297 POS EVENT LOG - Emergency backout has been pressed or released Typically No intervention needed. The customer has pressed and released the emergency backout button. If the errors are logged repeated, may be a button issue or relay issue. 1050297 POS EVENT LOG DO 0 0 Component(s)_Positioner_Event_logging 0 0 - Emergency backout has been released . Z:/heroic/poslayer.c 1425 1050297 POS EVENT LOG DO 0 0 Component(s)_Positioner_Event_logging 0 0 - Emergency backout has been pressed . Z:/heroic/poslayer.c 1440

1050263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 50263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift Limit Switch 0 0 - Limit switch 1 problem (prd: BB) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift_Limit_Switch 1 0 - Limit switch 2 

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
Component
Positioner Gantry Positioner Gantry Positioner Gantry
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.