The Customer complains of a Water or a fluid leak on the system.

Symptom

The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. If zero stock on 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next. The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next

Error message

INX100, 3610005 ALARM (! , 1.10) - Chiller warning, 1 min left, 2min left, and 3 min left, Debug: jedi-error-code=817h JEDI Error Code: 0817H chiller problem 1 minute Data Related to Error: 60 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY

error Code = 3602051 front, 3702051 Lat: Jedi: Chiller not working, debug Text += jedi-error=902h, tube cooling supply error, recovery Class = IH, major Function /= XRTechMgr 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed. System impact: X-ray unavailable. Displayed message : "Cooling Failure; Shut System down and call Service". Generally seen in system boot-up phasis or power issues. 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, 

Applies to

Models
Innova
Product
Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Component
Coolix XR Tube Chiller Coolix XR Tube Chiller Coolix XR Tube Chiller
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.