Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova105000110502635026310501031050042

INX100, Lost All Gantry axis's drive or NO movements

Symptom

INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor

Error message

INX100: 1050001 BUDDY Carc AXIS ENABLE Timeout when activating buddy input enable OR timeout when activating K3 command (prd: AD) 1050001 BUDDY Carc AXIS ENABLE DO GantryAxis No Motion BUDDY Carc AXIS ENABLE 1 0 - Timeout when activating buddyinputenable OR timeout when activating K3 command (prd: AD) Z:/heroic/prd task.c 564 18 If Followed by 1050263 Lift axis limit switch error Hardware = 0003 TSG MCB code (prd: BC,BB) Troubleshoot lift limit switch issue. 1050001 BUDDY Carc AXIS ENABLE DO GantryAxis No Motion BUDDY Carc AXIS ENABLE 1 0 - Timeout when activating buddy input enable OR timeout when activating K3 command (prd: AD) Z:/heroic/prd task.c 564 18 The Carc Axis has detected a failure on the buddy MCB (Lift) and logged this error. If Followed by 1050263 Lift axis limit switch error Hardware = 0003 TSG MCB code (prd: BC,BB) Troubleshoot lift limit switch issue.

1050263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 50263 FRT LIFT AXIS SWITCH ENGAGED - Lift_Limit_Switch 1 0 - Limit switch X problem (prd:BB or BC) 1050263 FRT LIFT AXIS SWITCH ENGAGED WR GantryAxis No Motion Lift Limit Switch 0 0 - Limit switch 1 problem (prd: BB)

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems
Component
Positioner Gantry Positioner Gantry Positioner Gantry
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues