GE Healthcare · X-ray VascularInnova360208538003313602016360208736020500000
INX100, PRO, IQ+ Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor
Symptom
INX100, PRO, IQ+ Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor. Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor
Error message
KV REGULATION SPITS. 3602085, error Text = Jedi: too many tube spits, debug Text += jedi-error=316h, Spit Max error, data related to error: 8, recovery Class = AR, major Function /= XRTechMgr KV REGULATION SPITS. System impact: X-ray unavailable. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service". May be preceded by error 3800331 Bad actual techniques recieved in aquisition, and followed by 3602016 Degraded Image Quality 3602087 Tube spits error details kV reg on steady state: 7 3602087 Jedi: Tube spits error details DO XRTechMgr control JEDI tube spits details 1 0 Anode: 0 Cathode: 0 Anode+Cathode: 0 kV reg on steady state: 7 kV reg on kV rise: 0 XRTechMgr.cpp 2272 38 2007 INX100: RTAC logbook indicates 3800331 Pulse is not ok during a not-Trial acquisition. The mA does not regulate during an Exposure The RTAC logbook indicates 3800331 Pulse is not ok during a not-Trial acquisition. The mA does not regulate during an Exposure. The mA feedback during an exposure is unregulated. The Jedi is not able to regalutate the mA and the mA demand and mA feedback is both high and low of the mA demand during an exposure. Review the RTAC logbook for the root
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Innova Jedi Innova Jedi Innova Jedi
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.