Pular para o conteúdo principal
GE Healthcare · MRExcite224530560811122450576080092245050607807

Unable to Scan Diffusions due with Z-Axis Current Distortion Fault.

Symptom

Unable to Scan EPI Diffusion With Z-Axis Current Distortion Fault and Gradient Drivers Hysteresis Test Fails on Z-Axis See Long Description Unable to scan EPI Diffusion protocols due to Z-axis Current Distortion Fault. This is the only type of scan failing. Then, when running Gradient Driver diagnostics, it fails with the errors shown below logged, showing a Gradient Hysteresis test failure. Tue Jul 1 16:10:51 2008 2245050 2 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 607807 Object: SCP Test Task GRADIENT DRIVER TESTS - The GP is reporting Z Axis Undervoltage Fault. Hysteresis Tue Jul 1 16:10:52 2008 2245053 2 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 607908 Object: SCP Test Task GRADIENT DRIVER TESTS - The GP is reporting a Gradient Amplifier Z Axis Current Distortion Fault. Hysteresis-> Tue Jul 1 16:10:53 2008 2245057 2 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 608009 Object: SCP Test Task GRADIENT DRIVER TESTS - The Z Axis gradient amplifier failed to go to Ready when commanded. Hysteresis-> Tue Jul 1 16:10:54 2008 2245305 2 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 608111 Object: SCP Test Task A fault was detected during execution of the Hysteresis Test. Check previous error messages for details. Perform a TPS Reset and try again.

Error message

2245305 A fault was detected during execution of the Hysteresis Test. See Long Description 2245305 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 608111 Object: SCP Test Task A fault was detected during execution of the Hysteresis Test. Check previous error messages for details. Perform a TPS Reset and try again.

2245057 The Z Axis gradient amplifier failed to go to Ready when commanded. Hysteresis See Long Description 2245057 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 608009 Object: SCP Test Task GRADIENT DRIVER TESTS - The Z Axis gradient amplifier failed to go to Ready when commanded. Hysteresis->

2245050 The GP is reporting Z Axis Undervoltage Fault. Hysteresis See Long Description 2245050 FB-MR1 diagCoord grad_lib.c 921 Diagnostic: Grad Hysteresis Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 607807 Object: SCP Test Task GRADIENT DRIVER TESTS - The GP is reporting Z Axis Undervoltage Fault. Hysteresis

2245053 The GP is reporting a Gradient Amplifier Z Axis Current Distortion Fault. Hysteresis See Long Description 2245053 FB-MR1 diagC

Applies to

Models
Excite
Product
Excite HD For 12.0 1.5T Systems only.
Software
12.0 Excite HD and 3T Excite HD products only
Component
2334862-2 ACGD SGA PS ASM W/FRU PACKAGING See Long Description 2334862-2 Part Type: GP REPAIRABLES Part Weight: 2.18 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ACGD SGA PS ASM W/FRU PACKAGING FRU: Yes Status: Orderable This supply is for use with HFD, HFD-S, and ACGD Cabinets. ** WARNING - POSSIBLE PERSONAL INJURY. HEAVY OBJECT - THE POWER SUPPLY WITH CASE WEIGHS APPROXIMATELY 240 LBS (109 KG). Assistance to lift this product mechanical (Dollies) or Additional personnel] is required. 212002950 May 27, 2009
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues