GE Healthcare · MRExcite2257210225223922611762252133225236070727
SCP did not respond to the start packet of WavRec and Startup Timeout was detected on the Drivers Control Board Due to t…
SCP did not respond to the start packet of WavRec and Startup Timeout was detected on the Drivers Control Board Due to the Driver Board.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2257210 SCP did not respond to the start packet of WavRec. Mon Nov 22 10:57:41 2004 Error: 2257210 Host: MRI1-OC0 Process: WavRec File: WavRec.cc Line: 175 SCP did not respond to the start packet of WavRec. This may be due to a TPS Reset 2252239 Startup Timeout was detected on the Drivers Control Board 2261176 SRI to 16 Channel Switch Communication Error: An error occurred reading the serial ID on the 16 Channel Switch. 2261176 tempmr NSP SCP:SriAutoConfig 796 SRI to 16 Channel Switch Communication Error: An error occurred reading the serial ID on the 16 Channel Switch. Please check the connection between the SRI and switch and make sure the switch has power. 2261176 tempmr NSP SCP:SriAutoConfig 796 SRI to 16 Channel Switch Communication Error:An error occurred reading the serial ID on the 16 Channel Switch. Please check the connection between the SRI and switch and make sure the switch has power. 2252133 SDO Communication Failure was detected on the CANopen Protocol Node Detecting Failure = SCP Wed Aug 25 08:04:47 2004 2252133 2 MR-OC0 NSP SCP:sdo_segment_upload 1408 SDO Communication Failure was detected on the CANopen Protocol. Node Detecting Failure = SCP. Node ID = 4. Index
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- SecondOpinion Excite HD & HDx Driver Module 5110612-2 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.