GE Healthcare · X-ray VascularInnova6001051000025600101600302
Xray not available; Collimator power failure Call Service.
Symptom
Xray not available; Collimator power failure Call Service. The DL Monitor is displaying the message "Xray not available; Collimator power failure Call Service". Collimator blades are totally closed and cannot be opened using collimator command on TSSC.
Error message
Arcnet communication error issue. error Code = 600105, error Text = ARCNET Communication Failure followed by error Code = 1000025, error Text = ARCNET Communication Failure. Mainly due to Positionner, can be seen in application or in boot phasis. Arcnet communication error issue. error Code = 600105, error Text = ARCNET Communication Failure followed by error Code = 1000025, error Text = ARCNET Communication Failure. Mainly due to Positionner, can be seen in application or in boot phasis. INX100: 600101 Collimator Control error, switch application and retry; Positioner link timeout 600101 Collimator Control error ; switch application and retry IH XRBeamForm control Component(s) Collimator 1 0 Positioner link timeout XRBeamForm.cpp 4161 102 INX100: 600302 Collimator Contour Filter warning ;Contour Filter not booted 600302 Collimator Contour Filter warning ; continue DO XRBeamForm Contour Filter Component(s) Collimator 1 0 Contour Filter not booted XRBeamForm.cpp 4150
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.