3T RF Serial Link Failure 2254352 Due to the Lower Unit of the 35KW RF Amplifier.
Symptom
Unable to Boot or Power Up 3T MKS 35 kW RF Amp. Amplifier's LCD Display is all Black Squares. RF Amp Serial Link Errors The customer hit the Emergency Stop button which powers off the RF Amplifier. Afterward, the RF Amp could not be booted up. It didn't power up successfully. The RF Amp display is all “little black squares”, or all backlit characters. The FE checked all the fuses, including the three "hidden" fuses (See Service Note 67103 "35kW Amp Fuse Replacement" for details on these fuses), and none were blown. See Attachment for additional information. The customer hit the Emergency Stop button which powers off the RF Amplifier. Afterward, the RF Amp could not be booted up. It didn't power up successfully. The RF Amp display is all “little black squares”, or all backlit characters. The FE checked all the fuses, including the three "hidden" fuses (See Service Note 67103 "35kW Amp Fuse Replacement" for details on these fuses), and none were blown. See Attachment for additional information.
Error message
2254352 RF Amplifier Interface Serial Link Failure Sun Nov 5 12:07:40 2006 Error: 2254352 Host: HORIMR01 Process: NSP File: SCP:../rf_nb_serial Line: 1530 RF Amplifier Interface <-> RF Amplifier serial link failure. The serial link appears to be broken. Check the RF Amp power and the serial link.
Applies to
- Models
- Excite
- Product
- 3T Excite HDx 14.0 Software. The software that this solution is tied to is indicated by the Software concept below.
- Software
- 14.0 M5 Excite HDx HDi Platforms only.
- Component
- SecondOpinion MKS 3T 35kW RF Amp 5104896 See comments in resolution concept for second opinion requirements before ordering this part.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.