GE Healthcare · X-ray VascularInnova3002220056
Innova 2000: Degraded mode: Continuous fluoro.
Continuous fluoro.
Symptom
Innova 2000: Degraded mode: Continuous fluoro. Call Service and continue. Innova 2000: errors 4142, 4141 or 4172. Degraded mode: Continuous fluoro. Call Service and continue. Upon receipt of this error code, ECM will automatically switch to continuous fluoro degraded mode.
Error message
30022: POWER UNIT : EXCESSIVE CURRENT ON INV B: 20056: ECM : POWER UNIT IN RESET STATE DUE TO ERROR> AR: ECM: HWStatus=0017 User=0000 0000 42C7. 20056: ECM : POWER UNIT IN RESET STATE DUE TO ERROR: AR: ECM: HWStatus =0001 User=0000 0000 4260 30022 Power Unit : Excessive Current on Inverter B is referring to the Filament drive Inverter not the HV Inverter. See LD for complete error 30022: POWER UNIT : EXCESSIVE CURRENT ON INV B: AR: ECM: HWStatus=0017 User=0000 0000 42C7. 20056: ECM : POWER UNIT IN RESET STATE DUE TO ERROR: AR: ECM: HWStatus =0001 User=0000 0000 4260 30022 Power Unit : Excessive Current on Inverter B is referring to the Filament drive Inverter not the HV Inverter.
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- X-ray tube MX150V5 TH.13 X-ray tube MX150V5 TH.13 RELOAD: Part #: 2149522-2 *** OLC 2ND OPINION PART *** Part #: 2149522-2 Part Type: GP TUBES Part Weight: -5999940.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX150V5 TH.13 RELOAD FRU: Yes Status: Orderable Comments: If no stock on this pn you can order pn D2712C (fru up) SPelletier 23 january 2006 *** OLC 2ND OPINION PART *** Need to check Grid Tank / Cables / and Run-in & Stability process in case of noise. If replacing the tube due to arcing or tube spits the microgrid tank (2127280-2) should be replaced also per SN4621. Other FRUs: 40 & 70 degree sensors 2133581-2, Quick Disconnects Female 2343093, Male 2343091
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.