GE Healthcare · MR
LCC ALARM SYSTEM WITHOUT MAGNETIC FIELD.
Symptom
LCC ALARM SYSTEM WITHOUT MAGNETIC FIELD. LCC ALARM SYSTEM WITHOUT MAGNETIC FIELD, the SHeM is alarming because the Quench Detect sensor, reed switch, has changed state and is not detecting a magnetic field.
Error message
LCC ALARM SYSTEM WITHOUT MAGNETIC FIELD. LCC ALARM SYSTEM WITHOUT MAGNETIC FIELD, the SHeM is alarming because the Quench Detect sensor, reed switch, has changed state and is not detecting a magnetic field.
Applies to
- Product
- Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
- Software
- SHeM Proprietary Software 2.3.7. SHeM Proprietary Software 2.3.7 SHeM Proprietary Software 2.3.7.
- Component
- 2108790 REED SWITCH W/COVER for Magnet Monitor. Reed Switch used to detect magnetic Field by Magnet Monitoring devices. Previously pre-assembled to Run 830, Magnet Room Interface Cable (2222797), but is now available alone. See Long Description for FEMC Commments. FEMC Parts Comments: Part #: 2108790 Part Type: GP CONSUMABLES Part Weight: 0.99 LBR Repairable: No Returnable: No Hazardous Material: N Description: REED SWITCH W/COVER FRU: Yes Status: Orderable Parts Offered as: Current: 2108790 Harvested: Not Available Exchange: Not Available Comments: FLS - SWITCH MR SIGNA CONTOUR (VMX) MS06014 3-96 USED ON MR CONTOUR 3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.