Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor
Symptom
INx100: Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor. The system has detected a Detector Bumper sensor problem, Both switches of Collision Detection on the Detector side do not indicate same information, and Displays the warning message for the customer to attempt to re-initialize the detector collision sensor on boot up or during normal usage. Detector Collision Error; Press Detector front plate to re-init is displayed on the Innova Monitor. The system has detected a Detector Bumper sensor problem, Both switches of Collision Detection on the Detector side do not indicate same information, and Displays the warning message for the customer to attempt to re-initialize the detector collision sensor on boot up or during normal usage.
Error message
error Code = 1050168, either be HW 0004 or H:0x8 Text = FRT II BUMP, debug Text = - LIFT COLLISION (T:0x4A12 H:0x8 U:0x0000)., recovery Class = WR, major Function /= GantryAxis System impact: Half speed until system level1 collision is cleared. Displayed message : "Detector collision occurred. Please reverse motion to continue.". Will stop Bolus chase run too System impact: Half speed until system level1 collision is cleared. Displayed message : "Detector collision occurred. Please reverse motion to continue.". feedback, Says HW 004 but has a mismatch as the actual HW is H:0x8. this should either be HW 0004 or H:0x8 Will stop Bolus chase run too
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.