GE Healthcare · X-ray VascularInnova1050168

Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor

Symptom

INx100: Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova Monitor. The system has detected a Detector Bumper sensor problem, Both switches of Collision Detection on the Detector side do not indicate same information, and Displays the warning message for the customer to attempt to re-initialize the detector collision sensor on boot up or during normal usage. Detector Collision Error; Press Detector front plate to re-init is displayed on the Innova Monitor. The system has detected a Detector Bumper sensor problem, Both switches of Collision Detection on the Detector side do not indicate same information, and Displays the warning message for the customer to attempt to re-initialize the detector collision sensor on boot up or during normal usage.

Error message

error Code = 1050168, either be HW 0004 or H:0x8 Text = FRT II BUMP, debug Text = - LIFT COLLISION (T:0x4A12 H:0x8 U:0x0000)., recovery Class = WR, major Function /= GantryAxis System impact: Half speed until system level1 collision is cleared. Displayed message : "Detector collision occurred. Please reverse motion to continue.". Will stop Bolus chase run too System impact: Half speed until system level1 collision is cleared. Displayed message : "Detector collision occurred. Please reverse motion to continue.". feedback, Says HW 004 but has a mismatch as the actual HW is H:0x8. this should either be HW 0004 or H:0x8 Will stop Bolus chase run too

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Component
Positioner Gantry Positioner Gantry Positioner Gantry
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required