GE Healthcare · X-ray VascularInnova2210001

Bolus would set up and perform the mask exposures.

Symptom

INX100: Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort.. Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort. # 2. Issue: The Innova aborts at the beginning of the Mask run with error 1200021, TRIG received while no PRETRIG has been received yet! LastFrameId=0, on the first Bolus chase of the day after system power off Bolus run aborted: Bolus would set up and perform the mask exposures. At the end of the mask exposures it would abort. #2 issue, The Innova aborts at the beginning of the Mask run with error 1200021, TRIG received while no PRETRIG has been received yet! LastFrameId=0, on the first Bolus chase of the day after system power off

Error message

2210001 Positioner mismatch between virtual and real position Position xxxxx has an invalid status. Trigger without exposure. This description is not exact. The SUIF log was filled with this error. One for every step of the table. Mask is OK till the End and stops. Then XRAY is aborted. 2210001 Positioner mismatch between virtual and real position Position xxxxx has an invalid status. Trigger without exposure. This description is not exact. The SUIF log was filled with this error. One for every step of the table. Mask is OK till the End and stops. Then XRAY is aborted.

Applies to

Models
Innova
Product
X Innova 4100 X Do not use---------4100 systems 4100 systems
Software
Unity 3D M4 SP2 Unity 3D M4 SP2 Fwd Prod. DL Release : DL_UNITY_4.17.5 Ghost DL : 21.22.1 DL : DL_Unity_4.17.5 DL Atlas Core : 4.2-8_5 RTAC Atlas Core : 4.2-8_5 IDC : 5.26 Calypso : 4.37 Calypso Uptime : CLYUPT.UNITY_4.15 Positioner : RR POS LBY 1.4.4U_13 Jedi : P636RC1
Component
What PIB to order for Innova 2100, 3100, 4100 and all IQ system What PIB to order for Innova 2100, 3100, 4100 and all IQ system. @Innova2100IQ 3100/3100IQ 4100/4100IQ M3FWP All Unity systems 5147993-2 PIB V2 (back compatible) @Innova 3D Upgrade M3 Kit 5147993 PIB V2 (without firmware) – Not compatible to Innova 2100 @ Bolus M4 5134661-2 PIB V2 5142722 Bolus M4 software package Innova 2100IQ TSM3 5147588 PIB V2 for Innova 2100 (Back compatible to Innova 2100) @ Innova 2100IQ M3 5134661 PIB V2 ZENITH (Enables Positioner diagnostics) @Innova2100 IQ 3100/3100 IQ 4100/4100 IQ M3FWP All Unity systems 5147993-2 PIB V2 (back compatible) @Innova 3D Upgrade M3 Kit 5147993 PIB V2 (without firmware) – Not compatible to Innova 2100 @ Bolus M4 5134661-2 PIB V2 5142722 Bolus M4 software package Innova 2100 IQ TSM3 5145126 CPU Roadrunner CVC (back compatible to Innova IB) 5147588 PIB V2 for Innova 2100 (Back compatible to Innova 2100) @ Innova 2100 IQ M3 5134661 PIB V2 ZENITH (Enables Positioner diagnostics) @ Bolus M3 5124797-2 PIB V2 (OLD not used) @ Innova 3100 M4 5124797 PIB. (New board replacing the current model becoming obsolete) (OLD not used) @ Innova 4100 M3 (OLD not used) 2406459FRU PIB
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.