GE Healthcare · MRExcite224457022486092247127225234922448482244574
Air Conditioning failure in the Computer room.
Symptom
Unable to scan with message System Cabinet Temperature is Greater Than 50'C See long description This message is seen in the message block area, above the six icons on the scan desktop. Soon the message is seen to change to "System Cabinet temperature has returned to 40'C", and the process repeats several times (cycles back and forth between 50'C and 40'C). Reference PQR 13080986
Error message
2244570 The gradient amplifier failed to go to Ready when commanded. 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded.-> 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded. 2248609 The air temperature in the System Cabinet is greater than 50'C (122F) Mon Aug 22 12:32:49 2005 Error: 2248609 Host: MR3T Process: NSP File: SCP:IrfPciHWO Line: 1234 The air temperature in the System Cabinet is greater than 50'C (122F). Check equipment room temp, if warmer than normal contact site maintenance, else call GE Service. diags error is 2247127 2252349 The Driver Module has detected that Fan #2 is malfunctioning. Error 2252349 NSP SCP:DCB 363 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Unknown Coil: Unknown Scan: -1/-1 The Driver Module has detected that Fan #2 is malfunctioning.-> 2244848 The GP is reporting a Gradient Amplifier %c Axis OverC
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.