Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days
Symptom
Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days. See Long Description for full text of message. Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days Tube type at the end of the first sentence in message below can vary. The system has been configured to recognize a GE Medical Systems Tube. A 30 day period from the date of tube installation has been granted to allow time to manually verify the tube identity. Please call GE Medical Systems to dispatch a Field Service Engineer (FSE) to verify the tube configuration. Please allow a minimum of 10 days for the FSE to schedule verification. Verification should take no more than 30 minutes. If a GE Medical Systems FSE does not verify the tube identity within %s days, the system will revert to an "unrecognized tube" status, resulting in the following: - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.
Error message
Error: 200109172 Tube verification reminder: The system has been configured to recognize a GE Medical Systems Performix tube for a 30-day period. Error: 200109172 Host: ls16 Process: scanRx File: SIRx.cxx Line: 619 Function: Data Acquisition : OC Processing Tube verification reminder: The system has been configured to recognize a GE Medical Systems Performix tube for a 30-day period. Error: 200109172 Error: 200109173 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Mon Jul 31 15:13:28 2006 Error: 200109173 Host: ls16 Process: scanRx File: SIRx.cxx Line: 623 Function: Data Acquisition : OC Processing Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Error: 200109173 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within ## days, the system will revert to an "unrecognized tube" status. Mon Jul 31 15:13:28 2006 Error: 200109173 Host: ls16 Process: scanRx File: SIRx.cxx Line: 623 Function: Data Acquisition : OC Processin
Applies to
- Models
- HiSpeed, VCT, BrightSpeed
- Product
- HiSpeed QX/i - GOC2 103L.5_HSQXIM4 103L.4_HSQXIM4 102L.1_HSQXIM3 HiSpeed QX/i - GOC2 Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types GOC2 List of softwares the product can run 103L.5_HSQXIM4 103L.4_HSQXIM4 - obsolete 102L.1_HSQXIM3 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required