Can Not Boot Applications Software Due To ICN.

Symptom

Can Not Boot Application Software With VRE Errors See Long Description 2249418 Host: LJP MR 01 Process: diagCoord File: mgdArp.c Line: 154 Task ID: 0x7effdf0 Time: 1689 Object: APS Exception Class: Unknown Function: Software/Firmware/Config: N/A Network problem detected. Check MGD subnet network configuration. arpResolve failed for IP 10.0.0.102, numTries 2, delay 100 ticks. status = -1. Or, 2223859 Host: ghmr002 Process: NSP File: TardisReset.cc Line: 469 Exception Class: Unknown Function: Recon: Data Acquisition The TPS Reset failed because of a VRE reset failure. Or; 2223860 VRE reset failed on ICN icn1 with MAC address XX:XX:XX:XX:XX:XX Or, 2223885 Host: hde-mr Process: logermes File: vreBmcUpCheck.pl Line: 251 Exception Class: Shutdown Function: Host: NSP System startup failed due to failure to communicate with the VRE!-> Extended Error: The system startup failure is caused by the failure to communicate with all configured ICNs. Please check that power is applied to all ICNs. Please check the Ethernet connections to all ICNs. You may also run all Ethernet and IPMI tests under VRE Communication Diagnostics to verify connectivity. As a last resort, VRE Configuration may be required to recover.

Error message

2249436 Host Communications Communication Problem Between APS And VRE Mon Oct 8 08:30:39 2007 Error: 2249436 Host: LJP MR 01 Process: diagCoord File: cm init.c Line: 293 Task ID: 0x6d89800 Time: 2376 Object: APS Exception Class: Unknown Function: Software/Firmware: Host Communications Communication problem between APS and VRE. The APS could not notify the VRE that communication is established.

2223878 A process has crashed on the VRE (00 30 48 59 F0 64[icn1]). Process dpserver, signal causing the crash 7, time 001631, date: 2007-11-10, UTC 1194621391 2223878 HDe_mfg NSP VREReset.cc 1008 Exception Class: Unknown Function: Recon: Data Acquisition A process has crashed on the VRE (00:30:48:59:F0:64[icn1]). Process: dpserver, signal causing the crash: 7, time: 00:16:31, date: 2007-11-10, UTC: 1194621391. Extended Error: During a TPS Reset the VRE gets scanned for core files that were generated since the last TPS Reset or System Restart. Only one such message is generated even if there is more than once core file. The oldest core file found across all ICNs is listed in this message.

Applies to

Models
Excite, Signa
Product
Excite HDx Includes "Excite HDi" system. 14.0 Software only.
Software
14.0 M5 Excite HDx HDi Platforms only.
Component
SecondOpinion Image Compute Node 5127452 See comments in Resolution Concept for second opinion requirements before ordering this part.
Area
MR