Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova3602047

Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.

Symptom

Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76

Error message

error Code = 3602047, error Text = DC bus out of range, debug Text += jedi-error=501h, DC bus out of range, recovery Class = IH, major Function /= XRTechMgr System impact: X-ray unavailable. Displayed message : "Xray not available - Reset system; if problem persists, call Service".

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Component
INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2 INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2. Follow job card DR0182 for FRU replacement. Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-9-2EN Rev 1 and is provided for your reference from the Innova 2100-IQ, 3100/3100-IQ, 4100/4100-IQ DVD documentation. To view the most recent appropriate and detailed documentation, click to go to MY WORKSHOP INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2. Follow job card DR0182 for FRU replacement. Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-9-2EN Rev 1 and is provided for your reference from the Innova 2100-IQ, 3100/3100-IQ, 4100/4100-IQ DVD documentation. To view the most recent appropriate and detailed documentation, click to go to MY WORKSHOP
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.