96527 LightSpeed 4.X
Symptom
Cradle Drive Motion was prohibited by hardware Interference switches
Error message
Error: 182215 Motion was prohibited by hardware interferenceHardware Inhibit Switches 0x80fc. Mon Sep 27 20:29:03 2004Error: 182215 Host: ETC Process: Cradle File: cmcStart.c 1.60 7/23/96 7/23/96 Line: 404 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:29:03:355 Log Series: 32 HW/SW error: Motion was prohibited by hardware Interference switches. Hardware Inhibit Switches 0x80fc Current Position 27309 (.01 mm) Dir: 1 (0 = Out 1 = In [Gantry]) Positions 0 (.01 mm) 170900 (.01 mm) Mon Sep 27 20:29:03 2004 Error: 182215 Host: ETC Process: Cradle File: cmcStart.c 1.60 7/23/96 Line: 404 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:29:03:355 Log Series: 32 HW/SW error: Motion was prohibited by hardware Interference switches. Hardware Inhibit Switches 0x80fc Current Position 27309 (.01 mm) Dir: 1 (0 = Out 1 = In [Gantry]) Interference Positions 0 (.01 mm) 170900 (.01 mm)
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required