TPS fails Power Up Diagnostics Interprocessor Test with Error 2222135 on the IPG1 Display.
Symptom
TPS fails Power Up Diagnostics Interprocessor Test with Error 2222135 on the IPG1 Display The Inter processor test checks communication between the IPG and TPS CPU. When TPS reset is issued, it always initiates, but it does not conclude. The IPG stays in IPG BOOT state even when the console is started and before the application initiates. IPG does not go to the state IPG READY. Vd0 interface (BIT3) is not responding by pinging it's IP address 192.0.0.2.
Error message
2242546 SBAM Diags:Memory function test failure. Error occurs when running SBAM diags. Error: 2242546 Process: diags File: diagsMain.cc Line: 2348 SBAM Diags:Memory function test failure.(from ADSP processor) ADSP detected a failure in the bulk memory pattern test.(random mode access) Address :184a2803H Expected :00000000H Actual :00200000H SIMM :J04 2222279 SSI Trigger Test-Line Trigger failure Error occurs when running IPG Diagnostics. SSI Trigger Test - Line Trigger failure The number of SSI interrupts did not match the line frequency indicated in the MRconfig file. LineFreq (shown in file): %d Hz Actual: % Hz" 2236700 CERD Diags : Analog Rcvr Lpbk Test Failure Rcvr channel %d has out-of-range amplitude (possible gain error) Amplitude: %d, Min: %d, Max: %d, RHO mult: %d This error may occur due to warmup when a syscab is powered up, but should pass in 15-20 minutes. 2236700 CERD Diags : Analog Rcvr Lpbk Test FailureRcvr channel %d has out-of-range amplitude (possible gain error)Amplitude: %d, Min: %d, Max: %d, RHO mult: %dThis error may occur due to warmup when a syscab is powered up, but should pass in 15-20 minutes. 2236708 CERD Diags : Wideband Exciter LO PLL & uC Comm Tes
Applies to
- Product
- Profile 3 Ultrasparc CPU with AN8290Y gradients
- Software
- Profile Contour 7.67 Applies to Profile1 through 4 and Contour1 through 4. This is the last revision of software for this product line. Requires 7.66 LFC. 7.67 is a patch.
- Component
- 2115088-2 TYME-II board Profile, Contour
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Unable to Scan a Phantom With RF Errors.
- Diagnostics fail with 2236700 out-of-range amplitude Due to Receiver.
- Profile/Contour ADSP error 2242546 on the SBAM.
- Unable to Scan due to to incorrect Line Frequency selection in the Install Gui.
- Contour Fails IPG Board Level Diagnostics with error 2222279 SSI Trigger Test-Line Trigger failure.
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.